1, Specifications
Model
|
PYXE-80IR
|
Input Power
|
500W
|
Screen Size
|
5"LCD screen
|
Heating Type
|
Air jacked heating system with microcomputer control
|
Control Range
|
Ambient Temperature +5~50℃
|
Operating Ambient Temperature
|
+5~30℃
|
Temperature Stability
|
±0.3℃
|
CO2 Control Range
|
0~20%V/V
|
CO2 Control Accuracy
|
±0.1%(infrared sensor)
|
CO2 Recovery Time
|
After the door is opened for 1 minute,CO2 concentration recovery time is less than 6 minutes.
|
Temperature Recovery
|
After the door is opened for 1 minute,temperature recovery time is less than or equal to 15 min at constant temperature of 37℃.
|
Relative Humidity
|
Relative humidity can reach 95% through natural evaporation of water.Relative humidity level can be displayed.
|
Volume
|
80L
|
Interior Dimension (W*D*H)
|
400*450*500(mm)
|
Overall Dimension(W*D*H)
|
590*687*790(mm)
|
Carrying Bracket
|
2/6 pieces
|
Optional
|
/
|
Sterilization Cycles
|
24hrs(90℃ moist heat disinfection)0.5hrs(Ultra violet sterilization)
|
Disinfection Method
|
Disinfection methods include moist heat disinfection at temperature of 90℃ and disinfection by ultraviolet light.Users can choose one of the two methods based on specific applications
|
Model
|
PYXE-150IR
|
Input Power
|
700W
|
Screen Size
|
5"LCD screen
|
Heating Type
|
Air jacked heating system with microcomputer control
|
Control Range
|
Ambient Temperature +5~50℃
|
Operating Ambient Temperature
|
+5~30℃
|
Temperature Stability
|
±0.3℃
|
CO2 Control Range
|
0~20%V/V
|
CO2 Control Accuracy
|
±0.1%(infrared sensor)
|
CO2 Recovery Time
|
After the door is opened for 1 minute,CO2 concentration recovery time is less than or 6 minutes.
|
Temperature Recovery
|
After the door is opened for 1 minute,temperature recovery time is less than or equal to 15 min at constant temperature of 37℃.
|
Relative Humidity
|
Relative humidity can reach 95% through natural evaporation of water.Relative humidity level can be displayed.
|
Volume
|
150L
|
Interior Dimension (W*D*H)
|
480*530*610(mm)
|
Overall Dimension(W*D*H)
|
670*767*880(mm)
|
Carrying Bracket
|
3/10 pieces
|
Optional
|
3 glass door
|
Sterilization Cycles
|
24hrs(90℃ moist heat disinfection)0.5hrs(Ultra violet sterilization)
|
Disinfection Method
|
Disinfection methods include moist heat disinfection at temperature of 90℃ and disinfection by ultraviolet light.Users can choose one of the two methods based on specific applications
|
Model
|
PYXE-240IR
|
Input Power
|
1000W
|
Screen Size
|
5"LCD screen
|
Heating Type
|
Air jacked heating system with microcomputer control
|
Control Range
|
Ambient Temperature +5~50℃
|
Operating Ambient Temperature
|
+5~30℃
|
Temperature Stability
|
±0.3℃
|
CO2 Control Range
|
0~20%V/V
|
CO2 Control Accuracy
|
±0.1%(infrared sensor)
|
CO2 Recovery Time
|
After the door is opened for 1 minute,CO2 concentration recovery time is less than or 6 minutes.
|
Temperature Recovery
|
After the door is opened for 1 minute,temperature recovery time is less than or equal to
15 min at constant temperature of 37℃.
|
Relative Humidity
|
Relative humidity can reach 95% through natural evaporation of water.Relative humidity level can be displayed.
|
Volume
|
240L
|
Interior Dimension (W*D*H)
|
600*630*670(mm)
|
Overall Dimension(W*D*H)
|
788*837*940(mm)
|
Carrying Bracket
|
3/10 pieces
|
Optional
|
/
|
Sterilization Cycles
|
24hrs(90℃ moist heat disinfection)0.5hrs(Ultra violet sterilization)
|
Disinfection Method
|
Disinfection methods include moist heat disinfection at temperature of 90℃ and disinfection by ultraviolet light.Users can choose one of the two methods based on specific applications
|
2, Features
1> Microbe High-efficiency Filter
A high-efficiency microbe filter,which comes with a sterilization function,is installed at the CO2 gas inlet.Its filtration efficiency is 99.99 percent,capturing particulates with diameters equal and greater than 0.3um.The filtration system eliminates bacteria and particulates in the CO2 gas to create a healthy environment for reliable experiments
2> Door Frame Heating System
Haier CO2 incubator's outer door radiates heating energy into the inner glass door to prevent condensation from occuring.The dry inner door eliminates the possibility of microbial contamination that exists in condensate water.
3> Automatic Control of Circulating Fan Speed
The air flow inside the chamber can be automatically controlled based on the requirement of an experiment.This feature reduces the risks of drying out test samples
4> 90℃ High-temperature Moist Heat Disinfection System
Moist heat disinfection at high temperature of 90℃ can kill microbes and fungal spores on the inner surface of the incubator
5> Ultraviolet Sterilization System
Ultraviolet sterilization system is positioned on the rear wall inside the incubator.It is used for quickly and effectively disinfecting the inside of the incubator body to kill any floating bacteria circulating in the air and water vapor in humidifying tray.This method thereby prevents potential contamination to cell incubation
6> Fast Recovery of Test Environment
The incubator system operates with a perfect interaction of the high-precision infrared The incubator system operates with a perfect interaction of the high-precision infrared The incubator system operates with a perfect interaction of the high-precision infrared The incubator system operates with a perfect interaction of the high-precision infrared The incubator system operates with a perfect interaction of the high-precision infrared
7> Microcomputer Controller
A large-screen liquid crystal display is a standard feature for ease of operation and clear display.It is controlled by a microcomputer precisely,and it can display temperature, CO2 concentration,and relatively humidity
8> Built-in Water Tray Design
The floor of the inner door is by design an integral built-in water tray for humidification process.Pure water can be introduced directly to the water tray for a greater area of process.Pure water can be introduced directly to the water tray for a greater area of of contamination
9> Graphic Inquiry
In the incubation process,all key operational parameters such as temperature,humidity,CO2 concentration and door usage are shown in a graphic temperature,humidity,CO2 concentration and door usage are shown in a graphic
10> Door Action Actuated Control
temperature,humidity,CO2 concentration and door usage are shown in a graphic automatically stops temporally to reduce CO2 gas consumption,and temperature overshoot. When the door is closed,the system resumes operation automatically
11> CO2 Incubator
1) Easy to Clean: Standard features include stainless steel inner liner designed with Easy to Clean: Standard features include stainless steel inner liner designed with
2) Space Saving: Units are conveniently stackable to allow laboratory space fully utilized
3) Protection Safety: Alarm systems feature an independent over-temperature alarm system,and a sound,illuminator system,and remote alert system that report system, temperature,humidity,door ajar,and malfunction conditions.That alarm systems safeguard experiments effectively