    Medlab—U/4C501 Biologic Signal Collection systems

    Newly added and main improving points
    ①Adopt high resistance(10E12Ω , 3pF), low nose. low drift 8i high function’s amplifier fuse to be ready, so it has such advantages as strong anti—interference, good linear degree and high measuring accuracy.
    ②Adopt USB 2.0 structure to transmit data, so its velocity is more high, and guarantees data’s continuous collection.

    ③Add 9 stage Besil low-pass wave filter newly, bi close to ideal condition
    ④Add 50Hz hardware wave frame circuit and datum tracing circuit newly
    ⑤Enlarge inputting electrical level’s scope to ±1.2v ,it’s very important to this condition that there is higher polarization voltage though the signal is very weak.
    ⑥Magnifying times is from 1,2,5,to 5000 so it can adapt to many kinds of signals.
    ⑦When outputting voltage is to 100v outputting current is to 100ma from electrical stimulator, it will separate light from electricity and be safe.

    Amplifier technical index
    NoItemParameter''s demand
    1Channel''s number,Four—channel amplifier has the same function adjustable parameter control and part technology
    2Inputting mode.Tow sends balance inputs differentially
    3    Inputting resistance100M
    4Gain transverter1, 2, 5, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000 ,10000, 20000, 50000
    5Gain accuracy0.5% (FS) ( an hour''s preliminary heating later)
    6Gain accuracy0.05%(FS) (an hour''s preliminary heating later)
    7Gain stability0.1 percent of full degree
    8Linear degree<1%
    9Distortion factorDC—30KHZC+0.5db—3db
    10Nose<3 MVRMS( Inputting short circuit, at maximum gain 30k wide band, it will convert to in putting end) <2uvRMS(Inputting short circuit, at maximum gain 30k wide band, it will convert to outputting end )
    11Common mode''s restrain>100db
    12Time drift<3MV/H (Inputting short circuit, at maximum gain, it will convert to inputting end)
    13Temperature drift<3mv/h(Inputting short circuit, at maximum gain, it will convert to outputting end )
    14Upper limit frequencyWhen voltage is DC—30kHz, its transverter is 10, you also can input upper limit frequency freely
    15Wave filter character9-stage Besil low-pass wave filter
    16Time constantDC 5s,2s,1s,0.2s,0.002s, 0.001s, 0.005s, adds up to 9 transverters altogether, you can switch freely
    1750 Hz wave frameHave but attenuate 32 db
    18Datum tracingHave and overcome datum drift
    19Monitor functionMonitor four channels freely
    20Note drop functionFour channel all can note including drops, drop velocity


    Stimulator parameter

    No
    Item
    Parameter''s demand
    1
    Range
    0-100v''s distance 13/mv
    2
    Outputting current
    100mm
    3

    Wave width

    0.1-600ms, program adjustable distance is 0.1ms
    4
    Delay
    1-250ms, program adjustable distance is 0.1ms
    5
    Operating mode
    Alone stimulation, crossing stimulation main period stimulation, automatic intermission stimulation, automatic range adjusting stimulation automatic wave width adjusting stimulation, automatic frequency adjusting stimulation
    6
    Stimulation pulse value
    Free
    7
    Stimulation series length
    free
    8
    Stimulation series intermission
    Free
    Operating table
    1
    Backing system
    Win2000/Winxp
    2
    Data transmission
    Full velocity USB structure.
    bio-equip.cn
    Established in 2004,headquarter in Anhui, branch in Beijing, Shanghai we are a professional manufacturer, Serving the basic medical and biological research field for animal experiment equipment development, production, sales and service as a professional technical enterprise
Request Infomation
Request Infomation: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Infomation

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Infomation:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.