美国徕博labomed,AAS-4000原子吸收光谱仪,AAS-4000原子吸收分光光度计(AAS-4000 ATOMIC ABSORPTION SPECTROPHOTOMETER)
型号:AAS-4000
价格:请致电:010-67529703
品牌:美国徕博labomed

美国徕博labomed


      AAS-4000原子吸收光谱仪(AAS-4000原子吸收分光光度计,AAS-4000  ATOMIC ABSORPTION SPECTROPHOTOMETER)


Atomic Absorption Spectrophotometer
Fully Automatic Combined Flame and Graphite Furnace System
Model AAS-4000 

View Brochure by Flipbook

PDF Brochure



Atomic Absorption Spectrophotometer AAS-4000 is a superior instrument for the research laboratory, and is an advanced and affordable system with high sensitivity that generates accurate and reproducible measurements. The AAS-4000 spectrophotometer is accurate, reliable, and is an exceptional value. With its built-in, computer-controlled Air/Acetylene flame, titanium alloy burner and high-efficiency glass nebulizer design, the system provides optimal and reproducible results for micro and macro samples with high resolution. 
Atomic Absorption Spectrophotometer AAS-4000 has a powerful built-in software which permits this instrument to be linked to a computer and a printer to display the photometric and spectral data on the PC monitor. Atomic Absorption Spectrophotometer AAS-4000’s enhanced transmission and full reflection makes this atomic absorption spectrophotometer highly effective and reduces noise.

One of its advantages is its accurate wavelength, ease of operation, versatile software applications, and effortless optional accessory installation. This instrument provides for automatic switching between the flame and graphite furnace, and is widely used for analyzing samples for Agricultural, Food, Geological, Clinical, Metal, Petrochemical, Environmental, Mining and Pharmaceutical applications.

It is easy to manipulate, and is fully automated, allowing for automatic adjustment of the lamp current and position, the burner head position, the negative voltage, and the gas flow. Safety is our primary concern, and the Atomic Absorption Spectrophotometer AAS-4000 allows for constant monitoring of the burner head, the flame, the ignition, air pressure, and drain status, to ensure the optimum functioning of the instrument.

Atomic Absorption Spectrophotometer AAS-4000 has a highly effective nebulizer, the sensitivity of the Cu 2?g/ml is more than 0.28Abs.

Labomed, Inc. is certified by ISO 9001-2013, has CE Conformity and is FDA Licensed.

Top of the Page

Features

  • The instrument has a motorized 8 hollow cathode lamp turret which allows the automatic positioning and optimization of each hollow cathode lamp by the software.
  • The control of the gas flows for the fuel gas (C2H2) of the burner is also carried out directly from the software, thus allowing optimization of the instrument for the best analytical parameters for a selected analysis.
  • Two methods of background correction are available. The first utilizes a Deuterium Arc lamp and the second is the proven method of Self Reversal.
  • High precision minimal optics ensures maximum light throughput to the computer controlled Czerny-Turner Monochromator.
  • The location of the wavelength and peak selection is automatically controlled from the software.
  • The spectral bandwidth is automated and is available with a choice of five slit sizes.
  • The electronic parameters for the photomultiplier tube detector, the hollow cathode lamp current and the balancing of the absorbance and background energies are controlled from the software.
  • The ignition of the flame is computer controlled and the various safety interlocks offer a very safe operating system.

Safety

  • The flame conditions are continuously monitored and should the flow rates change, an audible alarm sounds.
  • The pressure of the support gas (oxidant) is monitored constantly. If the pressure changes, then the flow of the fuel gas will be stopped and the flame will be safely extinguished.
  • A sensor monitors the level of liquid in the drain and will prevent ignition if too slow. The flame will also be extinguished if the level of liquid in the drain changes significantly.
  • A flame sensor monitors the flame and safely turns off the gas flow to the burner if the flame suddenly extinguishes.
  • The burner is identified by a switch making it impossible to light without the burner being fitted.
  • An emergency flame off button is installed in case a problem is observed. The flame can be extinguished safely.

Top of the Page

Technical Specifications

Elements That Can Be Tested By AAS-4000

List of Hollow Cathode Lamps

Accessories

Items included in the shipping of the AAS-4000

Description

Quantity

AAS-4000

1

Graphite furnace power supply

1

HCL Socket(1,2,3,4,5,6,7,8)

8

Control Cable (For Furnace Power Unit)

1

Power Cord (For Furnace Power Unit,)

1

Liquid Trap

1

Nebulizer

2

Hollow Cathode Lamp(Mn)

1

Hollow Cathode Lamp (Cu)

1

Hollow Cathode Lamp (Cd)

1

Hollow Cathode Lamp ( Hg)

1

Power Cord

1

RS-232 Cable

1

Nebulizer Manual

2

AAWIN Software

1

AAWIN Software Manual

1

Instruction Manual for AAS-4000

1

AAS Cookbook

1

Dust cover for main unit

1

Water Tubing Sleeves

1

Transition Joint

2

Dust cover for graphite furnace

1

Graphite Tubes with Platform

10

Slot ted head screw M3X10

2

Push-in Fitting(Pus06-00)

1

Push-in Fitting(100400600)

1

O Rings 14×1.8

4

Fuses for power (40A)

2

Fuses for power (0.5A)

1

Fuses for power (3.15A)

4

Socket Screw Wrench

1

Reflection mirror

1

Cutting Blade

1

Tweezers

1

Pipette(Finland,5-50uL)

1

Pipette Tip

200

Argon Tube(Ф6×1,white,10m )

10

Water Tube(Ф8×1,white,20m)

20

Acetylene Tube(Ф8ID,red,10m )

10

Air Tube(Ф8ID,green,10m)

10

Air Tube(Ф6×1,white,1m )

1

 

Accessories that are more economical 
to purchase locally from local producers

Description

Quantity

Notes

Computer

1

 

 
Argon gas

1

Purity higher than 99.99%


Air Regulator

2

 

Circulating Cooling System

1

 

Water Purification System

1

 

Oil Free Air Compressor

1

 

Acetylene Gas

1

Purity higher than 99.99%

Air Switch or Equivalent Switch

1

 

Vent Fan

1

 

Optional Accessories that can be purchased locally or from Labomed, Inc.

Part Number

Description

Notes

Auto G-4000

Graphite Furnace Auto Sampler

Measures 76 samples at one time automatically

H-4000

Hydride Generator

The argon gas is necessary and purity needs to be better than 99.99%

Auto F-4000

Flame Auto Sampler

Analysis of 50 or more sample and calibration standards


Description

Quantity

Hollow Cathode Lamp(Al)

1

Hollow Cathode Lamp (Ag)

1

Hollow Cathode Lamp (B)

1

Hollow Cathode Lamp (Ba)

1

Hollow Cathode Lamp(Be)

1

Hollow Cathode Lamp (Bi)

1

Hollow Cathode Lamp (Ca)

1

Hollow Cathode Lamp (Cd)

1

Hollow Cathode Lamp(Ce)

1

Hollow Cathode Lamp (Co)

1

Hollow Cathode Lamp (Cr)

1

Hollow Cathode Lamp (Cu)

1

Hollow Cathode Lamp(Dy)

1

Hollow Cathode Lamp (Er)

1

Hollow Cathode Lamp (Eu)

1

Hollow Cathode Lamp (Fe)

1

Hollow Cathode Lamp(Ga)

1

Hollow Cathode Lamp (Gd)

1

Hollow Cathode Lamp (Ge)

1

Hollow Cathode Lamp (H)

1

Hollow Cathode Lamp(Hf)

1

Hollow Cathode Lamp (Ho)

1

Hollow Cathode Lamp (In)

1

Hollow Cathode Lamp (K)

1

Hollow Cathode Lamp(La)

1

Hollow Cathode Lamp (Li)

1

Hollow Cathode Lamp (Mg)

1

Hollow Cathode Lamp (Mo)

1

Hollow Cathode Lamp (Na)

1

Hollow Cathode Lamp (Nb)

1

Hollow Cathode Lamp(Nd)

1

Hollow Cathode Lamp (Ni)

1

Hollow Cathode Lamp (Os)

1

Hollow Cathode Lamp (Pr)

1

Hollow Cathode Lamp(Sb)

1

Hollow Cathode Lamp (Sc)

1

Hollow Cathode Lamp (Se)

1

Hollow Cathode Lamp (Si)

1

Hollow Cathode Lamp (Sm)

1

Hollow Cathode Lamp (Sn)

1

Hollow Cathode Lamp(Sr)

1

Hollow Cathode Lamp (Ta)

1

Hollow Cathode Lamp (Tb)

1

Hollow Cathode Lamp (Te)

1

Hollow Cathode Lamp(Th)

1

Hollow Cathode Lamp (Ti)

1

Hollow Cathode Lamp (Tl)

1

Hollow Cathode Lamp (Tm)

1

Hollow Cathode Lamp (U)

1

Hollow Cathode Lamp (V)

1

Hollow Cathode Lamp(W)

1

Hollow Cathode Lamp (Zn)

1

Hollow Cathode Lamp (Zr)

1

Hollow Cathode Lamp (K)

1

Hollow Cathode Lamp(Au)

1

Hollow Cathode Lamp (Ir)

1

Hollow Cathode Lamp (P)

1

Hollow Cathode Lamp (Pb)

1

Hollow Cathode Lamp (Pt)

1

Hollow Cathode Lamp (Rb)

1

Hollow Cathode Lamp(Re)

1

Hollow Cathode Lamp (Ru)

1

Hollow Cathode Lamp (Y)

1

Hollow Cathode Lamp (Cs)

1

Hollow Cathode Lamp(Lu)

1

Hollow Cathode Lamp (Yb)

1

Hollow Cathode Lamp (Rh)

1