Syringe Heater Kit
Heater Kit is shown for demonstration purposes. Syringe pump and syringe are not included with Heater Kit.
|
Suggested List Price: $399 USD
|
|
|
Model: HEATER-KIT-1LG
|
Model: HEATER-KIT-5SP
|
Description:
Thermo-Kinetic Heat Clamp for syringes that require temperature-controlled dispensing. Heats up to 185°C.
Specification Notes:
-
Available in 2 versions:
-
1LG Heating Pad: 3.5" x 3.0" LxW (9 cm x 7.5 cm)
-
5SP Heating Pad: 20" x 0.625" LxW (50 cm x 1.5 cm)
-
Heater Kit includes control unit and primary syringe heater pad 1LG version or 5SP version.
-
Multiple syringe heater pads can be attached to the control unit, under restricted conditions.
-
Set point and other parameters retained in memory
-
Digitally sets the heater set point
-
Controller will heat the syringe and hold the set temperature using an on/off or Thermo-kinetic control algorithm.
-
Dual temperature sensors in primary heating pad.
-
Alarm modes with multiple layers of protection to prevent temperature overrun.
-
Additonal heat protection for the pump may be needed when heating syringes above 100°C.
-
If you are in a country where the voltage is above 120V, you must purchase a step-down transformer (Model: PWR-220-110-E) along with the Heater Kit.
-
Detailed Description
|
|
|
Second Heating Pad
|
现货询价
|
|
|
Model: HEATER-PAD2-1LG
|
Model: HEATER-PAD2-5SP
|
Model
|
Size
|
Attaches a Second Heating Pad To:
|
HEATER-PAD2-1LG
|
3.5" x 3.0" LxW (9 cm x 7.5 cm)
|
HEATER-KIT-1LG
|
HEATER-PAD2-5SP
|
20" x 0.625" LxW (50 cm x 1.5 cm)
|
HEATER-KIT-5SP
|
|
|
|
Third and Additional Heating Pads
|
现货询价
|
|
|
Model: HEATER-PAD3-1LG
|
Model: HEATER-PAD3-5SP
|
Model
|
Size
|
Attaches a Third+ Heating Pad To:
|
HEATER-PAD3-1LG
|
3.5" x 3.0" LxW (9 cm x 7.5 cm)
|
HEATER-PAD2-1LG
|
HEATER-PAD3-5SP
|
20" x 0.625" LxW (50 cm x 1.5 cm)
|
HEATER-PAD2-5SP
|
|
Specification Notes:
-
Only use identical primary and secondary heater pads together.
-
Each syringe heater control unit uses only the primary heating pad to sense temperature. All secondary heater pads connected to that control unit function according to temperature at the primary heater pad.
-
Careful consideration should be taken when using secondary/slave heater pads.
-
For different temperatures or variable environments, use separate control units with primary heater pads.
-
Plugging more than 12 syringe heater pads onto one controller is not recommended.
-
Detailed Description
|
|
|
Ana-Box Closed Loop Analog Sensor Interface
|
Model: ADPT-ANABOX-11
|
现货询价
|
|
Description:
-
Vary the pumping rate in proportion to a variable voltage input
-
Start or stop pump at set voltages
-
Vary the pumping rate to maintain a voltage window
-
Attaches to any pump in the NE-1000 or NE-9000 Series
-
Click Here For A Detailed Description
|
|
|
Foot Switch
|
Model: ADPT-FOOTSW-2
|
现货询价
|
|
Description:
-
Start, stop, or send a signal to a pumping program
-
20 foot cable
-
Quick and easy setup
-
Utilizes the TTL logic port on the pump
-
Attach to any pump in the NE-1000 or NE-9000 Series for remote operation
|
|
Foot Switch Extender
|
Model: CBL-TTL-EXT
|
Suggested List Price: $45 USD
|
Description:
-
100 foot extension cable for the foot switch
|
|
Hand Pendant
|
Model: ADPT-HAND-SW
|
现货询价
|
Description:
-
Hand held pendant for remote operation of pump
|
|
|
Pump-to-PC RS-232 Primary Network Cable
|
Model: CBL-PC-PUMP-7 (7 ft. cable)
|
现货询价
|
Model: CBL-PC-PUMP-25 (25 ft. cable)
|
现货询价
|
|
Description:
-
Allows full control of pump or other device from a computer
-
DB-9 adapter connects to 9-pin serial port (25-pin adapters available upon request)
-
Utilizes the RS-232 communications port of device
-
Available in 7' and 25' length cable
-
Quick and easy setup
-
Download FREE pump terminal emulator
|
|
|
RS-232 to USB Converter
|
Model: CBL-USB232
|
现货询价
|
|
Description:
-
Adds an RS-232 serial port to your computer by attaching to a USB port
-
Includes software driver CD
-
Attaches to cable CBL-PC-PUMP-7
|
|
|
Pump-to-Pump Secondary Network Cable
|
Model: CBL-NET-7 (7 ft. cable)
|
现货询价
|
Model: CBL-NET-25 (25 ft. cable)
|
现货询价
|
|
Description:
-
Allows networking of two or more pumps or other device to a single computer
-
Quick and simple setup
-
Utilizes the RS-232 communications port of device
-
Available in 7' and 25' length cable
-
Requires first device to be connected with primary network cable
|
|
|
Dual Pump Plumbing Kit
|
Model: P-DKIT
|
现货询价
|
|
Description:
-
For use with our continuous infusion system or dual infusion system
-
Provides dual check valves for two syringes, withdraw will pull fluid from a reservoir and infusion will output into a separate line
-
The kit is pre-assembled - just attach the syringes
-
Each dual check valve uses 6" of 1/8" ID tubing connected to a Y connector, one for reservoir and one for output; each Y-connector has 5' of tubing to make connections to your application. Two 50 mL NormJect® Syringes are included
|
|
|
|
Pump Synchronization Cables
|
Model: CBL-DUAL-3
|
现货询价
|
|
Description:
-
Used for creating a continuous infusion system, dual infusion system, or one of the other 2 pump automation modes.
-
Establishes a communications link between two pumps using the RS-232 serial ports on the pumps.
-
Replaces cable CBL-TTL-1, unless the use of the TTL ports for synchronization is preferred
-
Download User Manual
|
|
Model: CBL-TTL-1
|
现货询价
|
|
Description:
-
Used for creating a continuous infusion system or dual infusion system
-
Synchronize pumping direction of two pumps so that they change directions, start, and stop as one unit
-
Utilizes the TTL logic port on pump - See new version above for using the RS-232 ports
-
7' cable
-
Quick and easy setup
|
|
|
Lockout Mode Disable Key
|
Model: ADPT-LOCKOUT
|
现货询价
|
|
Description:
-
For use with a syringe or peristaltic pump's Lockout Mode
-
Prevent unauthorized or accidental changes to the settings by locking the keypad
-
The Lockout Disable key unlocks the keypad and allows settings to be changed
-
Attaches to the TTL logic port on the syringe or peristaltic pump
-
Quick and easy setup
|
|
|
OEM Starter & Net Kits:
For NE-5XX OEM models only
|
Model: OEM-STARTER
|
现货询价
|
|
Description:
|
|
Model: OEM-NET
|
现货询价
|
|
Description:
-
Power supply and secondary cable only. For use when networking two or more OEM NE-500 syringe pumps together. Must use the secondary cable in order to complete this application.
|
|
|
Single Valve Control Box
|
Model: ADPT-VALVE-INTERFACE-1
|
现货询价
|
|
Description:
-
Attach your 12V DC valve and the control box will open or close your valve according to the pumping direction
-
Utilizes the TTL logic port on syringe pump
-
Includes power supply for valve
|
|
|
Dual Valve Control Box
|
Model: ADPT-VALVE-INTERFACE-2
|
现货询价
|
|
Description:
-
Attach your two 12V DC valves and the control box will open or close your valves according to the pumping directions of your two pumps
-
Includes CBL-TTL-1 cable to allow synchronized pumping between two pumps
-
Utilizes the TTL logic ports on both syringe pumps
-
Includes power supply for valves
|
|